Consultor Eletrônico



Kbase P12544: Dynamics 2.0A AppServer wouldn't start due to invalid parameter file
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   2/3/2005
Status: Verified

FACT(s) (Environment):

Progress 9.1D
Dynamics 2.0A

SYMPTOM(s):

AppServer process wouldn't start.

Message from server : Startup Procedure Failed (8113)

IOException reading message from server : <IOException_string> (8117)

IOException reading message from server : java.io.EOFException: pipe to server broken (8117)

ERROR: cannot start server. (8100)

Exception unbinding broker (not bound) : <ExceptionMsg_string> (8525)

Exception unbinding broker (not bound) : <AppServer name> (8525)

The AppServer was being started with a parameter file (-pf).

CAUSE:

The parameter file (.pf) specified for the AppServer was incorrect.

FIX:

Confirm that the parameter file (.pf) within the C:\Program Files\Progress Dynamics directory is the correct copy with accurate settings.