Consultor Eletrônico



Kbase P11388: Operating System encounters hardware failure on File System where Progress Binaries are installed.
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   16/10/2008
Status: Unverified

SYMPTOM(s):

Operating System encountering hardware problem

Database abnormally terminated.

Memory Violation 49

Prostrct unlock cannot gain access to the database.

Can not establish a single user session to database.

Scan of database using proutil DBRPR failed to finish.

CAUSE:

Hardware failure caused file corruption on the filesystem where the Progress installation and database resided.

FIX:

1. Backup existing Progress install and database files.
2. Remove the Progress Installation.
3. Reinstalled Progress.
4 Attempt single user session to database and perform a dump and load.

If a single user session cannot be established to the database, restored the database from backup.