Status: Verified

FACT(s) (Environment):

Progress 9.1B
SCO UnixWare 7.1.1

SYMPTOM(s):

AppServer server processes don't always get assigned a PID.

CAUSE:

No Caldera PTF's or maintenance patches are applied to UnixWare 7.1.1.

FIX:

Apply Caldera UnixWare maintenance release M2.

To verify that the M2 maintenance release is installed, run the following UNIX command:

pkginfo|grep patch

The following "pkginfo" output will confirm whether the M2 patch has been applied:

patch uw711m2 UnixWare 7, Release 7.1.1 Maintenance Pack 2