Consultor Eletrônico



Kbase P10444: Error 126 on Test Connect - ODBC Merant 3.7 32-bit - wrong host or service
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   15/10/2008
Status: Verified

FACT(s) (Environment):

Progress 9.1D

SYMPTOM(s):

Configuring ODBC Datasource using MERANT 3.7 32-bit Progress returns error 126 when Test Connect.

Specified Driver could not be loaded due to system error 126 Merant 3.70 32-bit Progress

On a Windows platform, error code 126 translates to "ERROR_MOD_NOT_FOUND = specified module could not be found."

Entry for MERANT version exists in the REGISTRY under:
HKEY_LOCAL_MACHINE\SOFTWARE\ODBC\ODBCINST.INI\MERANT (version)

Registry Driver and Setup value data portions of the registry key point to the correct location of PGPRO915.DLL and the PGPRO915S.DLL files.

Client Networking product license installed

CAUSE:

The ODBC Data source is not configured correctly. Entries are missing in the Hosts and Services files.

FIX:

Set the Host and the Service correctly

1) Control Panel -> Data Sources ODBC
2) Select the ODBC Data Source in question -> Configure -> General Tab
3) Ensure that the "Host Name" and "Port Number" are valid entries