910819-kas01probkup Parameters Are Incorrect in the Documentation

There is a documentation bug for the parameters for version 6
of probkup. The parameters given in the documentation are
incorrect. In fact the parameters are as in the version 5
documentation for probkup.
FOR OFF LINE BACKUPS USING PROBKUP:
Instead of -io, the option should be -o.
Instead of -vs, the option should be -s.

The new parameter scan given for version 6 of probkup gives an invalid
parameter. The scan option was intended but is not supported.

FOR ON-LINE BACKUPS USING PROBKUP:
the option -vs is CORRECT.

(3/10/94) UPDATE - 6.3E and later versions use -vs and -bf for probkup
options as they are documented. (MJD)