Kbase 30151: Installation Error 139 on HP-UX 11 When Running Proinst From root (/) Directory
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   5/10/1998
Solution ID: P151

FACT(s) (Environment):

Progress 9.1C
HP-UX 11

SYMPTOM(s):

INSTALLATION ERROR (139): The entered configuration information is incorrect. Re-enter the configuration data.

Running on X-Windows client where TERM variable is set to dtterm

NEED to be able to run proinst from root (/) directory

CAUSE:

The cause is primary the set TERM and where you are running proinst

FIX:

If you need to run proinst from root (/) directory, then set TERM=xterm. Notice that 'xterm' is in lowercase.