Kbase 30150: Installation Error 139 on HP-UX 11 on X-Windows Where TERM=dtterm
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   5/10/1998
Solution ID: P150

FACT(s) (Environment):

Progress 9.1C
HP-UX 11

SYMPTOM(s):

INSTALLATION ERROR (139): The entered configuration information is incorrect. Re-enter the configuration data.

Running proinst from root (/) directory

Running on X-Windows client where TERM variable is set to dtterm

CAUSE:

The cause is primary the TERM and where you are running proinst

FIX:

Start proinst from another directory other than root if your TERM variable is set to dtterm.