Consultor Eletrônico



Kbase 22047: New -extravc Startup Parameter and the VALUE-CHANGED Trigger
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   23/05/2002
SUMMARY:

This Solution describes the functionality of the undocumented client startup parameter, -extravc.

In Versions 8.x and 9.0B, when clicking on the current row of a browse, the VALUE-CHANGED trigger is fired. In version 9.1A and higher, this trigger is only fired if the value has actually changed.

SOLUTION:

Beginning with the patch Version 9.1B01, a new client startup parameter (-extravc) has been added in order to ensure the Version 8.x behavior can still be used.