Consultor Eletrônico



Kbase 21623: Report Builder: Error (98) and (4781) After NetSetup Installation
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   15/01/2005
Status: Verified

SYMPTOM(s):

Trying to open Report Builder after a Netsetup installation.

** Unable to open file: <file-name>. Errno=<number>. (98)

** Unable to open file: convmap.cp. Errno=2. (98)

You are not licensed to run <product name>. (4781)

You are not licensed to run Progress Report Builder. (4781)

CAUSE:

PROCFG and PROCONV variables not set in Registry.

FIX:

Create a new environment variable "PROCFG" and "PROCONV" in the Windows registry as follows:

1) Start > 'Run' > Open: regedit

2) Go to HKEY_LOCAL_MACHINE\SOFTWARE\PSC\PROGRESS\9.1x\Startup

3) Select the menu option Edit > 'New' > String Value.

The Name must be PROCFG and the Data
<network drive>:\DLC91x\progress.cfg

4) Repeat step 3. But the Name must be PROCONV and the Data
<network drive>:\DLC91x\convmap.cp

Example:

HKEY_LOCAL_MACHINE\SOFTWARE\PSC\PROGRESS\9.1C\Startup

PROCFG E:\DLC91x\progress.cfg

E:\ is the network drive.