Consultor Eletrônico



Kbase 13140: AS/400 SNA error message PCS error 40
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   17/03/2003
Status: Unverified

FACT(s) (Environment):

Progress AS400 Dataserver

SYMPTOM(s):

PCS error: 40, insufficient real-mode memory, from ReceiveAndWait.(4833)

Error during initial receive from AS/400. (2492)

Failed to connect to AS/400 database. (2467)

CAUSE:

These errors indicate that the Client has run out of REAL-MODE Memory.
That PC/Support or other protocols could not be loaded and therefore it could not connect to the AS/400.

FIX:

Use some type of memory manager and reduce the real-mode memory loaded that's the memory area between 640.

In the AS/400 JOBLOG you will see this entry:
PRO0001 10 DIAG PROGRESS:_FATALERROR: QOLFIO receive, ret=83, rsn=4002