Kbase 20788: 6275 and 8113 Errors Starting AppServer on AS/400
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   10/16/2008
Status: Unverified

FACT(s) (Environment):

IBM AS/400

SYMPTOM(s):

Error when starting the Progress AppServer on AS/400

<opname> failed: WebSpeed error <ws_error>, System error <errno>, <errordesc> (6275)

Message from server : <serverMsg> (8113)

Message from server: find_Section of /Progress/V91A/properties/ubroker.properties for section Ubroker
failed: WeebSpeed error 10004, System error 0, Specified Service
Name does not exist (6275)
Ubroker (8113)

CAUSE:

The Coded Character Set Identifier (CCSID) is incorrectly set on the AS/400. By default, the CCSID is set to the *SYSVAL code page.

FIX:

Set this value to 37. To do this, change the user profile of the user who started the Progress AdminServer (the default is Progress). Change the setting for Coded Character Set Identifier.