Kbase 20608: Release Note: V9.1B HP-UX 32-bit and Patch PHSS_22543
Autor |
  Progress Software Corporation - Progress |
Acesso |
  Público |
Publicação |
  3/26/2001 |
|
SUMMARY:
This solution discusses the interrelation between HP-UX patch PHSS_22543 and Progress Version 9.1B06. This version is the minimum Progress version that functions on a machine with this HP-UX patch installed.
EXPLANATION:
There is interdependency between 32-bit Progress for HP-UX and the HP-UX patch PHSS_22543 [aCC a.03.30] and its successors. Progress Version 9.1B06 is the minimum version that functions on a machine with this HP-UX patch installed.
If an earlier release of Version 9 is installed, it stops running when the HP-UX patch is installed and the client gets a runtime
link error such as the following:
/usr/lib/dld.sl: Unresolved symbol: __head (data) from
/usr/lib/libC.2.
/usr/lib/dld.sl: Unresolved module for symbol: __shlinit (
(code) from /usr/lib/libstream.2
All Progress clients (_progres, _proapsv, _probuild, and orarx) have been rebuilt to function with the operating system patch installed in Version 9.1B06.
Any Probuilt client must have its ld script regenerated and the executable re-linked.