Kbase P187588: Error 14365 with icudata-psc.dll starting GUI application
Autor |
  Progress Software Corporation - Progress |
Acesso |
  Público |
Publicação |
  11/05/2011 |
|
Status: Unverified
SYMPTOM(s):
Error 14365 starting GUI application
Could not load ICU library icudata-psc.dll . (14365)
Error 4 creating collator:PL.
Starting Polish client application that worked previously results in error 14365.
Errors in the database log file when starting the application are:
2011/05/04@14:39:36.032+0200] P-2720 T-4588 I SRV 2: (742) Login usernum 58, userid g005760 client type ABL , on PLDT8N4KQ4J using TCP/IP IPV4 address 163.157.12.135.
[2011/05/04@14:39:36.157+0200] P-2720 T-4588 I SRV 2: (14369) Error loading ICU collation ICU-PL, connection aborted.
[2011/05/04@14:39:36.157+0200] P-2720 T-4588 I SRV 2: (14658) Previous message sent on behalf of user 58, server pid 2720, broker pid 3756. (5512)
[2011/05/04@14:39:36.173+0200] P-2720 T-4588 I SRV 2: (739) Logout usernum 58, userid g005760, on PLDT8N4KQ4J.
FACT(s) (Environment):
The application has not been changed or upgraded.
The progress installation has not been changed or upgraded.
Trying to open one of the batch files for edit in the <DLC>\bin directory results in "Access is denied".
All Supported Operating Systems
OpenEdge 10.x
CAUSE:
The installation location of OpenEdge has had its file permissions changed making some of it inaccessible to the end users. In this case a 3rd party company had affected the installtion.
FIX:
Correct the OpenEdge installation permissions.