Consultor Eletrônico



Kbase P187319: Proquiet disable incorrectly reports database in BI Stall state.
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   06/05/2011
Status: Unverified

SYMPTOM(s):

Proquiet disable incorrectly reports database in BI Stall state.

Database hit BI Stall

proquiet <dbname> bithreshold <new higher value> given successfully

(6561) Forward processing continuing.

FACT(s) (Environment):

All Supported Operating Systems
OpenEdge 10.1C
OpenEdge 10.2x

CAUSE:

Bug# OE00207404

CAUSE:

In a situation where a database has hit a BI Stall point.
After the stall point has been released by using the command:
proquiet <dbname> bithreshold <new higher value bithreshold>
Any attempts to issue the command proquiet <dbname> disable will incorrectly report:
Database is in a Bistall Quiet Point - Request rejected.

FIX:

A bug has been filed on this situation.
The issue is cosmetic although it is misleading.
No stall is in effect.
The attempt to disable the quiet point should indicate the database is not quieted.