Kbase P185204: OE Architect: TEMP-TABLE NO-UNDO option ignored when defining class is loaded
Autor |
  Progress Software Corporation - Progress |
Acesso |
  Público |
Publicação |
  4/1/2011 |
|
Status: Unverified
SYMPTOM(s):
OE Architect: TEMP-TABLE NO-UNDO option ignored when defining class is loaded
The TEMP-TABLE NO-UNDO option appears not to be respected when loading the TEMP-TABLE defining class in OE Architect
The TEMP-TABLE NO-UNDO option appears to be ignored when a class containing the NO-UNDO TEMP-TABLE definition is instantiated by running a procedure in an OpenEdge Architect session
FACT(s) (Environment):
The TEMP-TABLE NO-UNDO option is respected when the same code is run in an OpenEdge Procedure Editor session
The TEMP-TABLE NO-UNDO option is respected when the same code is run from the command line of an OpenEdge Proenv
Windows
OpenEdge 10.2B
OpenEdge Category: Architect (OEIDE)
CAUSE:
Bug# OE00206288
FIX:
None at this time