Kbase P135730: Error messages in Trend Database Compaction job .out file.
Autor |
  Progress Software Corporation - Progress |
Acesso |
  Público |
Publicação |
  12/11/2010 |
|
Status: Unverified
SYMPTOM(s):
Error messages in Trend Database Compaction job .out file.
Value 108837338071 too large to fit in INTEGER data type. (13682)
Value <value> too large to fit in INTEGER data type. (13682)
** Unable to update CPU Field. (142)
** Unable to update System Memory Field (142)
Value 2445772123 too large to fit in INTEGER data type. (13682)
FACT(s) (Environment):
OpenEdge Management 3.1x
All Supported Operating Systems
CAUSE:
Bug# OE00175858
FIX:
Upgrade to 10.2B01
If it is not possible to upgrade at this time the following will serve as a workaround:
Redefine the offending fields in the trend database as INT64 or DEC to match the data type of the source database.