Consultor Eletrônico



Kbase P135730: Error messages in Trend Database Compaction job .out file.
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   12/11/2010
Status: Unverified

SYMPTOM(s):

Error messages in Trend Database Compaction job .out file.

Value 108837338071 too large to fit in INTEGER data type. (13682)

Value <value> too large to fit in INTEGER data type. (13682)

** Unable to update CPU Field. (142)

** Unable to update System Memory Field (142)

Value 2445772123 too large to fit in INTEGER data type. (13682)

FACT(s) (Environment):

OpenEdge Management 3.1x
All Supported Operating Systems

CAUSE:

Bug# OE00175858

FIX:

Upgrade to 10.2B01

If it is not possible to upgrade at this time the following will serve as a workaround:
Redefine the offending fields in the trend database as INT64 or DEC to match the data type of the source database.