SYMPTOM(s):

SessionPool : NoAvailableSessions[CONNECT FAILURE: Unable to resolve hostname (8821)

IOException reading message from server : java.io.EOFException: pipe to server broken (8117)

Fatal transport failure -14. (5487)

FACT(s) (Environment):

AppServer starts without error most of the time.
Database started via scripts using proserve command.
Progress 9.x
OpenEdge 10.x
All Supported Operating Systems

CAUSE:

The database had not started and the commands being issued resulted in these errors.

FIX:

Start the databases as usual, however, add a pause of a few seconds, prior to starting the AppServer to insure databases had started prior to starting the AppServer.