Kbase P170198: Cannot start WebSpeed broker
Autor |
  Progress Software Corporation - Progress |
Acesso |
  Público |
Publicação |
  7/22/2010 |
|
Status: Unverified
SYMPTOM(s):
Cannot start WebSpeed broker
Following messages in broker log file:
ServerSocketsIPC <operation> IOException : <IOException_string> : <IOExceptionMsg_string> (8127)
ServerSocketsIPC read() IOAusnahme : java.io.EOFException : NULL (8127)
ServerIPCException in <funcName> : <ServerIPCException_string>. (8119)
ServerIPCE-Ausnahme in getServerIPCMsg() : ServerIPC error: ubServerSocketsIPC.read() IOException: null. (8119)
Unexpected msg from server :
version= 109
type= 1 UBTYPE_ADMIN
src= 0 DEFAULT_UBSRC
rq= 0x1 UBRQ_ADMIN
tlvBuflen= 0x0
rqExt= 0x0
rsp= 0x0 UBRSP_OK
rspExt= 0x0
src= 0
adRq= 4 ADRQ_SERVER_TERMINATE
rsp= 0 ADRSP_OK
msglen= 0
buflen= 0
ERROR: cannot start server. (8100)
FEHLER: kann Server nicht starten. (8100)
Exception unbinding broker (not bound) : <ExceptionMsg_string> (8525)
Ausnahme Abbinden Broker (nicht gebunden) : vub_wsWtWeb (8525)
Following messages from application compile:
** Unable to understand after -- "<string>". (247)
** Nach "get-from-form-fields" unverständlich. (247)
** <program> Could not understand line <number>. (198)
** C:\Programme\Progress\src\web\method\cgiutils.i Kann Zeile 434 nicht
verstehen. (198)
FACT(s) (Environment):
vub_wsWtWeb is Webspeed application name
Windows
OpenEdge 10.2B
OpenEdge Server Technology Category: WebSpeed
CAUSE:
Incompatible PSE (eScript) version.
FIX:
Install the correct eScript version compatible with the OE version.