Kbase P160466: Getting error 6396 and 1554 in the webspeed server log when the propath folder path is longer than 4
Autor |
  Progress Software Corporation - Progress |
Acesso |
  Público |
Publicação |
  03/01/2011 |
|
Status: Verified
SYMPTOM(s):
Getting error 6396 and 1554 in the webspeed server log when the propath folder path is longer than 44 characters in windows vista enterprise
WTA: npp_enable_connections() failed with error number: -51. (6396)
The server did not start successfully. (1554)
FACT(s) (Environment):
WebSpeed agent stays at starting an dies
Only one path is added to the defualt propath of the webspeed agent
Windows Vista Enterprise
OpenEdge 10.2B
CAUSE:
The cause of this issue is unknown at the time of writing.
FIX:
Use shorter path or append the non-default path on the propath in the application