Kbase P167536: After Image Archiver log not listing correct sequence of backup and what ai files should be applied
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   18/06/2010
Status: Unverified

SYMPTOM(s):

After Image Archiver log not listing correct number of AI file to be rolled forward for the backup file.

After Image Archiver log not listing correct sequence of AI file that should be applied to a restored database.

FACT(s) (Environment):

All Supported Operating Systems
OpenEdge 10.1x

CAUSE:

Bug# OE00125939

FIX:

If using 10.1A, upgrade to 10.1A02.
If using 10.1B, upgrade to 10.1B03.
If using a later version of OpenEdge this problem should already be corrected.