Consultor Eletrônico



Kbase P151567: Raw-transfer not working when Runtime Security option is enabled
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   07/04/2010
Status: Unverified

SYMPTOM(s):

Raw-transfer not working when Runtime Security option is enabled

Permission to read field denied. (14361)

RAW-TRANSFER statement failed due to stale schema for table ''. (11425)

enable record authenticated client sessions, runtime permission checking and disallow blank userid

FACT(s) (Environment):

Record authenticated client sessions enabled
Runtime permission checking enabled
Disallow blank userid enabled
All Supported Operating Systems
OpenEdge 10.2A

CAUSE:

Bug# OE00181799

FIX:

Upgrade to 10.2A02 or later release