Kbase P156500: Visual Designer fails to load class with error "Unable to resolve type information for type" after i
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   25/11/2009
Status: Unverified

SYMPTOM(s):

Visual Designer fails to load class with error "Unable to resolve type information for type" after installing Service Pack 2 for OpenEdge 10.2A

Visual Designer cannot load this class.
Unable to resolve type information for type <Control Name>

Code worked prior to installing Service Pack 2 for OpenEdge 10.2A

FACT(s) (Environment):

OpenEdge 10.2A02 upgrades Infragistics controls from version 8.1.20081.1000 to 8.1.20081.2150
OpenEdge 10.2A
OpenEdge 10.2A02 32-bit Service Pack
Windows

CHANGE:

Upgraded to OpenEdge 10.2A02

CAUSE:

The exact cause is unknown at the time of this writing

FIX:

Update the version of the Infragistics controls listed in the assemblies.xml file of the affected Project to match the newer version number