Kbase P147041: FOCUSED-ROW change in behavior when running ABL window together with GUI for .NET Forms
Autor |
  Progress Software Corporation - Progress |
Acesso |
  Público |
Publicação |
  10/2/2009 |
|
Status: Unverified
SYMPTOM(s):
FOCUSED-ROW change in behavior when running ABL window together with GUI for .NET Forms
FOCUSED-ROW returns the row number when the mouse button was moved down instead of the row when it was moved up
FACT(s) (Environment):
In the MOUSE-MOVE-UP trigger of the browser, there is a message showing the FOCUSED-ROW of the browser
The problem is observed when the ABL window is run with .NET
The problem is observed when pushing the mouse button on a row of the browser and then moving (with the mouse button pushed) down to another row
The problem is not observed if the rows are just clicked (without moving the mouse)
The problem is not observed when the ABL window is run without .NET
Windows
OpenEdge 10.2A
CAUSE:
Bug# OE00185264
FIX:
Upgrade to OpenEdge 10.2A02 or later