Kbase P147041: FOCUSED-ROW change in behavior when running ABL window together with GUI for .NET Forms
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   10/2/2009
Status: Unverified

SYMPTOM(s):

FOCUSED-ROW change in behavior when running ABL window together with GUI for .NET Forms

FOCUSED-ROW returns the row number when the mouse button was moved down instead of the row when it was moved up


FACT(s) (Environment):

In the MOUSE-MOVE-UP trigger of the browser, there is a message showing the FOCUSED-ROW of the browser
The problem is observed when the ABL window is run with .NET
The problem is observed when pushing the mouse button on a row of the browser and then moving (with the mouse button pushed) down to another row
The problem is not observed if the rows are just clicked (without moving the mouse)

The problem is not observed when the ABL window is run without .NET

Windows
OpenEdge 10.2A

CAUSE:

Bug# OE00185264

FIX:

Upgrade to OpenEdge 10.2A02 or later