Consultor Eletrônico



Kbase 18583: Report Builder 8.3A Collates On Win95 Not On WinNT
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   26/01/2006
Status: Verified

FACT(s) (Environment):

Windows 32 Intel
Windows NT 32 Intel/Windows 2000
Progress 8.x
Progress 9.x

SYMPTOM(s):

Report Builder does NOT collate multiple reports.

CAUSE:

Since collation is the default expected behavior this issue has been logged as a bug for the variant behavior on Windows NT.

FIX:

Customers wishing a non-collated report may set it to run from an available Windows NT system until such time as the varying behavior is corrected.