Kbase P144224: Shutting down a managed DB with OE Management or DBMAN takes minutes
Autor |
  Progress Software Corporation - Progress |
Acesso |
  Público |
Publicação |
  06/04/2009 |
|
Status: Unverified
SYMPTOM(s):
Shutting down a managed DB with OE Management or DBMAN takes minutes
Nothing is logged to the db.lg file for several minutes
The dbagent and_mproshut processes are running in the system process list for several minutes after shutdown command
The shutdown command is immediately logged to admserv.log
FACT(s) (Environment):
All Supported Operating Systems
OpenEdge 10.1C
OpenEdge Management 3.1x
Database might shutdown eventually or proshut command needs to be executed
Shutting down the database with proshut works fine
CAUSE:
Bug# OE00171889
FIX:
Upgrade to OpenEdge 10.1C03 or a later release or upgrade to OpenEdge 10.2A where the issue no longer exists.