Consultor Eletrônico



Kbase P143888: OE Architect: Editor fails to insert the logical database name on Drag & Drop of fields and tables f
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   3/30/2009
Status: Unverified

SYMPTOM(s):

OE Architect: Editor fails to insert the logical database name on Drag & Drop of fields and tables from the DB Structure View.

Editor inserts the physical database name when field and table names are dragged from the DB Structure View and dropped into the Editor.

The "Automatically prefix fields and tables with database name" option is checked from Windows > Preferences > OpenEdge Architect > Editor.

FACT(s) (Environment):

Windows
OpenEdge 10.x
OpenEdge 10.2A

CAUSE:

Bug# OE00132385

FIX:

At this time, the prefixing of logical database names is not supported with the Drag & Drop of fields and tables from the DB Structure View to the Editor. As a workaround, use the Find/Replace (CTRL-F) functionality of the OpenEdge Architect Editor to replace the physical database name with the desired logical database name in the OpenEdge Architect Editor after each Drag & Drop action.