SYMPTOM(s):

Target OE Replication went down with errors 1028, 8999 and 10428

SYSTEM ERROR: Rollforward Apply AI note, BKUPDCTR=204, note updctr=254. (1028)

area <are>, dbkey <dbkey>, record type <recordtype> (8999)

Function dsaAIApplyNote failed in rpNOT_ProcessNoteBlock with error -30000. (10428)

Block processing ended in error at block 1925 in area 31. Fathom Replication cannot continue. (10495)

Unexpected error -30000 returned to function rpAGT_AgentLoop. (10504)

FACT(s) (Environment):

Restarting target and source database does not help
All Supported Operating Systems
OpenEdge 10.x
OpenEdge Category: Database

CAUSE:

The database block (an index one in this case) had a corrupted header, which was detected by Replication agent when applying the particular AI note causing Replication to stop.

FIX: