Consultor Eletrônico



Kbase 18345: Error 231. Starting Progress DB from Procontrol.
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   05/02/2004
Status: Unverified

FACT(s) (Environment):

Windows NT 4.0
Windows NT 4.0 Terminal Server Edition

SYMPTOM(s):

Attempting to start a database via the ProControl utility

** Invalid reference to a frame outside its scope. (231)

The Database can be started manually from the Command prompt.

CAUSE:

This error under Windows NT means ALL PIPE INSTANCES ARE BUSY.

FIX:

The Service Control Manager (Services.exe) creates a pipe for each of the services it starts. This pipe is used for interprocess communication between the Service Control Manager and the process of the service. The maximum number of pipe instances is hard-coded to 100.

There is a lack of resources on the system. Stop some services on the system and then try to start Procontrol again. If you still are not able to start databases. Put the additional
ot needed services startup type on manual. Reboot the server, start ProControl first, then start the other services.