Kbase P134904: Getting error 6383 when running WebSpeed code from OE Architect
Autor |
  Progress Software Corporation - Progress |
Acesso |
  Público |
Publicação |
  08/09/2008 |
|
Status: Unverified
SYMPTOM(s):
Getting error 6383 when running WebSpeed code from OE Architect
Agent did not return an HTML page (6383)
FACT(s) (Environment):
The WebSpeed Agent's PROPATH includes the project's path
OE Architect is connected to the remote Database
The Database is taken off line at night for backup but the WebSpeed broker is not restarted to make a connection to the database
Windows NT 32 Intel/Windows 2000
OpenEdge 10.1C
CAUSE:
The WebSpeed agent is not connected to the remote database.
FIX:
Restart the WebSpeed broker.