Consultor Eletrônico



Kbase P133300: Source and target databases will not synchronize after upgrading OE version
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   17/07/2008
Status: Unverified

SYMPTOM(s):

Source and target databases will not synchronize after upgrading OE version

Fathom Replication Agent cannot be configured because the required AI area (area-number>, sequence number <sequence-number> is not available. (10716)

Fathom Replication Agent failover_rfm cannot be configured because the required AI area (area-number>15, sequence number 5801 is not available. (10716)

FACT(s) (Environment):

OpenEdge Replication 10.x
UNIX
Windows

CHANGE:

Moving from an older version of OpenEdge to another one requiring Replication to be re-sourced

CAUSE:

User copied the previous versions .recovery files from the database directory to the new database location. This is what is causing the rpagent to look for sequence number 5801. Since this is a newly sourced source and target db, the sequence is 1.

FIX:

Remove the .recovery files and restart the source and target database.