Kbase P120766: Abnormal database shutdown with error 3715 in the log file on HP Itanium using Aries emulator
Autor |
  Progress Software Corporation - Progress |
Acesso |
  Público |
Publicação |
  02/01/2009 |
|
Status: Verified
SYMPTOM(s):
Abnormal database shutdown with error 3715 in the log file on HP Itanium using Aries emulator
SYSTEM ERROR: lkrels record <recid> not locked. (435)
Lock table overflow, increase -L on server (915)
SYSTEM ERROR: latch <latch-num> depth <levels>. (3715)
SYSTEM ERROR: latch 14 depth -1. (3715)
Creating protrace file <pathname>/<filename> (13638)
** Save file named core for analysis by Progress Software Corporation. (439)
SYSTEM ERROR: Releasing regular latch. latchId:<latch-num> (5028)
SYSTEM ERROR: Releasing regular latch. latchId: 14 (5028)
SYSTEM ERROR: Releasing multiplexed latch. latchId:<latch-num> (5029)
SYSTEM ERROR: Releasing multiplexed latch. latchId:32000 (5029)
SYSTEM ERROR: Releasing multiplexed latch. (5029)
Begin ABNORMAL shutdown code (2249)
protrace file contains:
ARIES64: Error occurred while writing core file for PA64 emulated application (Got signal 3). Core file may not be correct.
[HP ARIES32]: Core file for 32 bit PA-RISC application
Stack trace from _mprosrv on HPUX Itanium reads:
latunlatch
lkfree
lkrelsy
Stack trace from _proapsv on HPUX Itanium reads:
latunlatch
lklocky
cxLock
cxNext
FACT(s) (Environment):
Using Aries Emulator
HP-UX Itanium 64-bit machine.
HP-UX 11i 64-bit
HP-UX 11i Itanium
Progress 9.1E
OpenEdge 10.1A
Progress 9.1E 64-bit
CAUSE:
Aries is a binary emulator that transparently emulates 32-bit and 64-bit HP-UX PA-RISC applications on HP-UX IA-64 machines but is not a supported configuration.
FIX:
Upgrade from HP-UX PA-RISC (media id 173 or 175) to a HP-UX IA-64 (media id 186).
Contact Customer Service or your Sales Representative to request the platform upgrade.