Consultor Eletrônico



Kbase P132052: Procontrol fails after installing in a new server
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   03/06/2008
Status: Unverified

FACT(s) (Environment):

Windows
Progress 8.x
Progress 9.x

SYMPTOM(s):

Procontrol fails to start DB.

Error 231 Communicating with ProService

DB is set to start automatically in ProControl.

CHANGE:

DB was migrated to a new server

CAUSE:

Procontrol DB entry used wrong -H value.

FIX:

1) Modify -H value to use the correct hostname.
2) Stop Proservice.