Consultor Eletrônico



Kbase P130960: How to upgrade existing MSS/ODBC OE10.0x DataServer Schema holder to OE10.1C
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   9/13/2010
Status: Verified

GOAL:

How to upgrade existing ODBC OE10.0x DataServer Schema holder to OE10.1C

GOAL:

How to upgrade existing MS SQL Server OE10.0x DataServer Schema holder to OE10.1C

GOAL:

How to upgrade existing ODBC OE10.1A DataServer Schema holder to OE10.1C

GOAL:

How to upgrade existing MS SQL Server OE10.1A DataServer Schema holder to OE10.1C

GOAL:

How to upgrade existing pre ODBC OE10.1B DataServer Schema holder to OE10.1C

GOAL:

How to upgrade existing pre MS SQL Server OE10.1B DataServer Schema holder to OE10.1C

FACT(s) (Environment):

Windows NT 32 Intel/Windows 2000
ODBC DataServer
OpenEdge 10.x

FIX:

Follow the steps below to upgrade the ODBC DataServer Schema Holder:

1. Dump the .df from pre OE10.1C schema holder.
2. Edit the .df file to correct the ODBC driver version and save it
3. Create an empty Database on OE10.1C
4. Load the saved schema holder .df in to OE10.1C empty Database.
5. Use the Update/Add Table definitions tool on the DataServer > ODBC Utilities to bring or pull the tables again. The pull is required for DataServer to realize the conflict for 64-bit PROGRESS_RECID fix.