Kbase P103067: Error 4132 in application developed using Dynamics
Autor |
  Progress Software Corporation - Progress |
Acesso |
  Público |
Publicação |
  19/03/2009 |
|
Status: Verified
SYMPTOM(s):
Dynamics runtime
Horizontal resolution of display exceeds 1280 pixels
Error 4132 occurs in various parts of the application.
** Invalid character unit value <value>, Changed to 320. (4132)
FACT(s) (Environment):
Progress 9.1E
Progress 9.1D
OpenEdge 10.x
Dynamics
Windows
CAUSE:
Bug# OE00109938
CAUSE:
The Progress core client imposed a maximum frame width of 320 columns.
While the related errors could be either worked around or suppressed, this was not done for the Dynamics Runtime components.
FIX:
Upgrade to OpenEdge 10.1B or later release.
The limitations in the core client have been removed, thus solving this issue.