Consultor Eletrônico



Kbase P103067: Error 4132 in application developed using Dynamics
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   19/03/2009
Status: Verified

SYMPTOM(s):

Dynamics runtime

Horizontal resolution of display exceeds 1280 pixels

Error 4132 occurs in various parts of the application.

** Invalid character unit value <value>, Changed to 320. (4132)

FACT(s) (Environment):

Progress 9.1E
Progress 9.1D
OpenEdge 10.x
Dynamics
Windows

CAUSE:

Bug# OE00109938

CAUSE:

The Progress core client imposed a maximum frame width of 320 columns.
While the related errors could be either worked around or suppressed, this was not done for the Dynamics Runtime components.

FIX:

Upgrade to OpenEdge 10.1B or later release.

The limitations in the core client have been removed, thus solving this issue.