Kbase P127230: OpenEdge: Procedure Editor About Box shows wrong version information
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   29/11/2007
Status: Unverified

FACT(s) (Environment):

UNIX
OpenEdge 10.1B03 32-bit Service Pack
OpenEdge 10.1B03 64-bit Service Pack

SYMPTOM(s):

OpenEdge: Procedure Editor About Box shows wrong version information

Message displayed in the About Procedure Editor references OpenEdge Release 10.1A02:
About Procedure Editor
PROGRESS Procedure Editor
Release 10.1B03
OpenEdge Release 10.1A02 as of Thu Oct 12 22:08:42 EDT 2006
International Classes for Unicode:
Copyright ¸ 1999, International Business
Machines Corporation and others. All rights

Message displayed in the About Procedure Editor should reference OpenEdge Release 10.1B03:
About Procedure Editor
PROGRESS Procedure Editor
Release 10.1B03
OpenEdge Release 10.1B03 as of Fri Nov 2 21:03:50 EDT 2007
International Classes for Unicode:
Copyright ¸ 1999, International Business
Machines Corporation and others. All rights

CAUSE:

The $PROPATH environment variable, which is being set in the user .profile, points to the older OpenEdge Release 10.1A02 installation directories.

FIX:

Ensure that the $PROPATH environment variable points to the OpenEdge Release 10.1B03 installation directories.