SYMPTOM(s):
After-Imaging is not enabled. (2514)
AIW will not start when auto-started via Progress Explorer/AdminServer
AIW will not start from command line
AI Files added to the database successfully
CAUSE:
After-Imaging has not yet been enabled.
FIX:
If it has not been done so already, backup the database, and run the following command to enable after imaging:
rfutil dbname -C aimage begin