Consultor Eletrônico



Kbase P126480: Starting AIWs result in message After-Imaging is not enabled. (2514)
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   10/18/2007
Status: Unverified

SYMPTOM(s):

After-Imaging is not enabled. (2514)

AIW will not start when auto-started via Progress Explorer/AdminServer

AIW will not start from command line

AI Files added to the database successfully

CAUSE:

After-Imaging has not yet been enabled.

FIX:

If it has not been done so already, backup the database, and run the following command to enable after imaging:
rfutil dbname -C aimage begin