Consultor Eletrônico



Kbase P125369: How to configure -Mn above 512 in the Progress Explorer Tool.
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   18/02/2009
Status: Verified

GOAL:

How to configure -Mn above 512 in the Progress Explorer Tool.

FACT(s) (Environment):

Windows
Progress 9.x
OpenEdge 10.x

FIX:

The Progress Explorer Tool grays out the Maximum Server value, as well as the "OK" button in the defaultConfiguration Properties window when the Maximum Server Value is blank or above 512. This may be over ridden by entering the -Mn parameter in the "Other Server Arguments" box in this window.

ie:
-Mn 750