Consultor Eletrônico



Kbase P124892: Ai Management utility documentation has incorrect order for buseq in the format for archive line
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   7/12/2007
Status: Unverified

FACT(s) (Environment):

All Supported Operating Systems
OpenEdge 10.1x

SYMPTOM(s):

Ai Management utility documentation has incorrect order for buseq in the format for archive line

Backup sequence number of the backup value is listed out of order in ai management log file

buseq value is listed to be before aibegin-date

CAUSE:

Bug# OE00154312

CAUSE:

This is a Documentation bug.

FIX:

In Ai Management utility documentation on version 10.1A and 10.1B, the buseq value is listed to be before aibegin-date but it should be listed after aibegin-time.

10.1A and 10.1B documentation reads:

An archive line is formatted as follows:

Extent archive indicator,database,date,time,buseq,aibegin-date,aibegin-time,aiseq,extent-name,target-directory,target-extent-name

but should read as:

An archive line is formatted as follows:

Extent archive indicator,database,date,time,aibegin-date,aibegin-time,buseq,aiseq,extent-name,target-directory,target-extent-name