Consultor Eletrônico



Kbase P123275: Inserting data into RAW field via SQL92 causes string data, right truncated error
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   8/10/2007
Status: Unverified

FACT(s) (Environment):

OpenEdge 10.1A
OpenEdge 10.1B

SYMPTOM(s):

.NET based application uses SQL92 to access database

Doing an INSERT of binary data into a RAW field causes an error

[DataDirect][ODBC Progress OpenEdge Wire Protocol driver][OPENEDGE]Server crash likely.

Error: String data, right truncated. Error in column 1.

CAUSE:

Bug# OE00148910

CAUSE:

ODBC driver was incorrectly retrieving data from RAW fields

FIX:

Upgrade to OpenEdge 10.1B02