Kbase P123275: Inserting data into RAW field via SQL92 causes string data, right truncated error
Autor |
  Progress Software Corporation - Progress |
Acesso |
  Público |
Publicação |
  8/10/2007 |
|
Status: Unverified
FACT(s) (Environment):
OpenEdge 10.1A
OpenEdge 10.1B
SYMPTOM(s):
.NET based application uses SQL92 to access database
Doing an INSERT of binary data into a RAW field causes an error
[DataDirect][ODBC Progress OpenEdge Wire Protocol driver][OPENEDGE]Server crash likely.
Error: String data, right truncated. Error in column 1.
CAUSE:
Bug# OE00148910
CAUSE:
ODBC driver was incorrectly retrieving data from RAW fields
FIX:
Upgrade to OpenEdge 10.1B02