Consultor Eletrônico



Kbase 17966: 1078 errors using 100 megabit network cards.
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   26/05/1998
1078 errors using 100 megabit network cards.

DRAFT COPY - Currently under review and edit.

INTRODUCTION:
=============
If customers are experiencing 1078 error messages from their clients
after changing from 10 mgbit cards to 100 mgbit cards, there are a few
items to check for. Ping and telnet may or maynot be working in this
case.


PROGRESS ERROR NUMBER: ERROR TEXT: TYPE:
====================== ================================== =========
1078 TCP must be loaded and working before running multi-user PROGRES


POSSIBLE CAUSE OF ERROR:
========================
Two possibilites exist that make sense.

1) Network software errors. Strip out the network software from the
client and reinstall network software.

2) Ping and telnet are 32-bit utilites. They use either ws2_32.dll
(winsock 2 - 32 bit) or wsock32.dll (winsock 1 - 32 bit) Older
copies of progress are 16 bit and use winsock.dll. This dll may
be damaged or be missing. Check / replace this dll or move to a
32 bit version of Progress


DOES ERROR INDICATE CORRUPTION: IF SO, WHAT TYPE
======================================== =========================
no


REFERENCES TO WRITTEN DOCUMENTATION:
====================================
No references presently cover this issue.