Consultor Eletrônico



Kbase P124279: proutil conv910 fails
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   6/6/2007
Status: Unverified

FACT(s) (Environment):

OpenEdge 10.x
UNIX

SYMPTOM(s):

proutil conv910 fails

strange messages returned after the "VST Table Deletion has completed successfully. (6885)"

11058 message is replaced with truncated promsgs

Conversion completed, database is now in Progress OpenEdge Release 10 format. (11058)

SYSTEM ERROR: Memory violation. (49)

Stack trace from _proutil reads:

drSigFatal
__libc_sigaction
msgfnd
msgnCB
msgCB
dsmMsgnCallBack
drConv910

progress executables in the /usr/bin directory

CAUSE:

OpenEdge 10 was installed over the Progress 9 installation

FIX:

If needing to install to the previous installation directory, select the proinst option to delete the directory instead of installing
in the pre-existing path. In this way, the previous installation is cleaned up before the new version is installed.