Kbase P123431: Error 11996 occurs when attempting to execute Progress commands from PROENV
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   4/16/2007
Status: Unverified

SYMPTOM(s):

Attempting to use Progress command-line tools, such as PROSTRCT

Error 11996 occurs

The <ARG> parameter requires a numeric argument. (11996)

The -numsep parameter requires a numeric argument. (11996)

DLC\STARTUP.PF contains list of parameters but values are missing, for example:

-d
-numsep
-numdec

Errors seen during installation

CAUSE:

A problem occurred during installation resulting in the failure of the file tailoring process; required files exist but have not been customized to the current system and installation location.

FIX:

Option #1 - Recommended
Reinstall Progress/OpenEdge and ensure that the installation completes without error

Option #2
Add values to the parameters in DLC\Startup.pf. For example:

-d dmy
-numsep 44