SYMPTOM(s):

SDO query cannot be browsed by more than one SmartDataBrowser.

Switching an ADM2 smartDataBrowser between two smartDataObjects results in SDO query cannot be browsed error.

Using removelink and addlink to switch a smrtDataBrowse between 2 SDO's results in a message suggesting that the SDO is being browsed by 2 browsers.

CAUSE:

The SmartDataObject dataQueryBrowsed property has been set indicating that the SDO is already being browsed.

FIX:

When switching a smartDataBrowse between 2 SDO's, the SDO dataQueryBrowsed property should be set to indicate when the SDO is NOT being browsed.

For example:

{set dataQueryBrowsed FALSE h_SDO}.