Consultor Eletrônico



Kbase P122396: Error 4081 when running application
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   21/02/2007
Status: Unverified

SYMPTOM(s):

Error 4081 when running application

**Attribute <attribute> must be greater than or equal to 1 on <widget id>. (4081)

This attribute must be given a value greater than or equal to 1. For example, ROW and COLUMN can not be set to any number less than or equal to 0.

**Attribute attribute must be greater than or equal to 1 on widget id. (4081)

High resolution screen causes error 4081.

CAUSE:

The DPI resolution of the screen has affected application objects and its screen layout.

FIX:

Reduce the DPI setting of the display adapter. As an example, if the current setting is 120, reduce it to 90.