Kbase P122200: Procopy of a 10.1A database fails with 1119 error when using 10.1B
Autor |
  Progress Software Corporation - Progress |
Acesso |
  Público |
Publicação |
  25/11/2009 |
|
Status: Verified
SYMPTOM(s):
Procopy of a 10.1A database fails with 1119 error when using 10.1B
SYSTEM ERROR: wrong BI blk, read <dbkey> from <dbkey> (1119)
Stack trace from _dbutil reads:
bkRead
mvReadBlock
mv_copyutil
dbusProcopy
dbusExecute
FACT(s) (Environment):
All Supported Operating Systems
OpenEdge 10.1B
CAUSE:
Before-image was not truncated in 10.1A
FIX:
Truncate bi using OpenEdge 10.1A.
i.e: proutil <dbname> -C truncate bi