Kbase P120364: AppBuilder files saved in OE10.1A SP2 are not compatible with earlier version, get error 565
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   16/11/2006
Status: Verified

FACT(s) (Environment):

Windows
Progress 9.x
OpenEdge 10.x

SYMPTOM(s):

Cannot open a file in AppBuilder

FIND FIRST/LAST failed for table _U (565)


Invalid Handle for _U: OCX ?
Deleting Universal Object Record.

Trying to open a .w file with AppBuilder

Trying to open a .w file using an older AppBuilder version than 10.1A SP02

Code contains OCXs

Code has been saved in OpenEdge 10.1A02 Service Pack or later

CAUSE:

As result of bug fix 20060605-021 the structure of the AppBuilder code is changed in OE10.1A02. Therefore due to architectural changes in the way we store information, files opened and saved in 10.1A02 cannot be opened by *any* earlier version than 10.1A02.

FIX:

Progress doesn't support backward compatibility. Files created (or saved) with a newer version could never be opened using an older version. Open the file with the AppBuilder version you saved the file in first instance