Consultor Eletrônico



Kbase P119291: Getting error 1987 after upgrading from 10.0B to 10.1A
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   6/9/2009
Status: Verified

SYMPTOM(s):

Operation number 302 not supported in this release. (1987)

Operation number <number> not supported in this release. (1987)

Recompiled application code using 10.1A

FACT(s) (Environment):

OpenEdge 10.1A
All Supported Operating Systems

CHANGE:

Upgraded from OpenEdge 10.0B to OpenEdge 10.1A by installing into a different directory

CAUSE:

The icons used by the users to run the application had not been modified to point to the new OpenEdge 10.1A installation so the users were trying to run 10.1A r-code using the OpenEdge 10.0B executables

FIX:

Modify the icons used by the users to run the application so that they point to the OpenEdge 10.1A installation