Kbase P116932: OUTPUT TO device APPEND, hangs.
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   23/06/2006
Status: Unverified

FACT(s) (Environment):

OpenEdge 10.0B
OpenEdge 10.1A

SYMPTOM(s):

OUTPUT TO device APPEND hangs.

OUTPUT TO VALUE("lpt1:") APPEND.

Both the colon in the device name and also the APPEND option are given.

CAUSE:

This is a known issue being investigated by Development

FIX:

There are two workarounds to this issue:

1. Remove the colon from the device name. i.e.:

OUTPUT TO VALUE("lpt1") APPEND.
or
OUTPUT TO LPT1 APPEND.

2. Remove the APPEND option when printing to a device.