Kbase P116932: OUTPUT TO device APPEND, hangs.
Autor |
  Progress Software Corporation - Progress |
Acesso |
  Público |
Publicação |
  23/06/2006 |
|
Status: Unverified
FACT(s) (Environment):
OpenEdge 10.0B
OpenEdge 10.1A
SYMPTOM(s):
OUTPUT TO device APPEND hangs.
OUTPUT TO VALUE("lpt1:") APPEND.
Both the colon in the device name and also the APPEND option are given.
CAUSE:
This is a known issue being investigated by Development
FIX:
There are two workarounds to this issue:
1. Remove the colon from the device name. i.e.:
OUTPUT TO VALUE("lpt1") APPEND.
or
OUTPUT TO LPT1 APPEND.
2. Remove the APPEND option when printing to a device.