Consultor Eletrônico



Kbase P116496: After image switch of empty AI file fails, aimage lists shows multiple busy ai extents.
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   21/05/2007
Status: Verified

FACT(s) (Environment):

Progress 9.1E
OpenEdge 10.0x

SYMPTOM(s):

Can't switch to after-image extent it is full. (3773)

After image switch of empty AI file fails with error 3775.

Can't switch to after-image extent it is full. (3775)

After image new fails with error 3775.

Aimage list shows two busy ai extents.

rfutil <dbname> -C list reports two After Image files with status BUSY.

CAUSE:

Bug# OE00122951

CAUSE:

This issue is caused when:
a. the database has larges file enabled, and
b. the ai file in question has overgrown 2GB when it is switched.


FIX:

Upgrade to Progress 9.1E03, OpenEdge 10.0B04 or later where this issue has been addressed.

Unfortunately, this issue causes corruption of the after image files. After-imaging therefore needs to be re-baslined to allow after-image use again. In broad strokes, this requires a disable and re-enable of the full process to allow after image usage again:
rfutil dbname -C aimage end
<take a new backup of the live database>
rfutil dbname -C aimage begin.

For further information please refer to Progress Solution P1938, "How to use After-imaging (AI) to maintain a hotspare database" and the Progress Database Administration Guide and Reference.