Kbase P116206: Incremental Search property of Combo-box control CSCOMB32.OCX is broken
Autor |
  Progress Software Corporation - Progress |
Acesso |
  Público |
Publicação |
  30/12/2008 |
|
Status: Verified
SYMPTOM(s):
4GL/ABL: The Incremental Search property of the Crescent/SAX COMBO-BOX ActiveX control, CSCOMB32.OCX is broken.
The search is performed based on the first typed character only and not on all the character entered by the user as expected.
Using CSCOMB32.OCX version 4.50.0.3
This problem did not occur with CSCOMB32.OCX version 4.50.0.0 and earlier.
FACT(s) (Environment):
Windows
OpenEdge 10.0B
OpenEdge 10.1A
CAUSE:
Bug# OE00131095
FIX:
Upgrade to OpenEdge 10.1B or later. If upgrading to OpenEdge 10.1B or later is not feasible, then a workaround is to deploy one of the the older versions of CSCOMB32.OCX that do not have this problem. For example, version 4.32.0.0 distributed with Progress 9.1D or version 4.50.0.0 distributed with Progress 9.1E.